 Agilent Technologies N5394A DVI Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes
Data Sheet
Verify and debug your DVI designs more easily
Agilent Technologies N5394A DVI electrical performance validation and compliance software for Infiniium Series oscilloscopes provides you with a fast and easy way to verify and debug your digital visual interface (DVI) designs for add-in cards, cables and motherboard systems. The DVI electrical test software allows you to automatically execute DVI electrical checklist tests, and displays the results in a flexible report format. In addition to the measurement data, the report provides a margin analysis that shows how closely your device passed or failed each test. To make measurements with the N5394A DVI electrical test software, you also need the DVI Compliance Test Kit test fixtures, available through the DDWG1
1 Digital Display Working Group (www.ddwg.org)
or Silicon Image, for hardware clock recovery and making measurements. The N5394A DVI electrical test software performs a wide range of tests required to meet the DVI-1.0 electrical specifications for add-in cards, cables and motherboard systems as documented in section 4 of the base specification by the DDWG1. To meet signal quality requirements, your product must successfully pass compliance testing based on the DVI specification. You must perform the tests included on the checklist before you submit your product for full compliance testing. The N5394A DVI electrical test software helps you execute a subset of the checklist tests for transmitters (Tx) and cables that can be measured with an oscilloscope.
Features
The N5394A DVI electrical test software offers several features to simplify the validation of DVI designs: * Test setup wizard for ease-ofuse * All of the electrical tests specified by DVI test specification, full compliance of DVI tests * Measurement process configurability * Automated oscilloscope measurement setup * Test results report generation * Pass/fail margin analysis With the DVI electrical test software, you can use the same oscilloscope you use for everyday debugging to perform automated testing and margin analysis based on the DVI-specified test checklist.
N5394A saves you time
The N5394A DVI electrical test software saves you time by setting the stage for automatic execution of DVI electrical tests. Part of the difficulty of performing electrical tests for DVI is hooking up the oscilloscope, setting up the proper configuration, and then analyzing the measured results by comparing them to limits published in the specification. The DVI electrical test software does much of this work for you. In addition, if you discover a problem with your device, debug tools are available to aid in rootcause analysis. The N5394A DVI electrical test software offers the four fundamental DVI electrical tests. The software automatically configures the oscilloscope for each test, and it provides an informative results report that includes margin analysis indicating how close your product is to passing or failing that specification. For many tests, a selection is allowed on specific measurement parameters. Clock recovery of the TMDS clock is accomplished with the DVI Compliance Test Kit Clock Recovery Unit (CRU) board to ensure proper test results. See Table 2 for a complete list of the measurements made by the DVI electrical test software.
Easy test definition
The N5394A DVI electrical test software extends the ease-of-use advantages of Agilent's Infiniium Series oscilloscopes to testing DVI designs. The Agilent automated test engine walks you quickly through the steps required to define the tests, set up the test, perform the tests, and view the
test results. You can select a category of tests all at once, or specify individual tests. You can save tests and configurations as project files and recall them later for quick testing and review of previous test results. Straightforward menus let you perform tests with a minimum of mouse clicks.
Easy to follow task flow for configuring and running tests
Select one test or a group of tests with a single mouse click
Figure 1. The Agilent automated test engine guides you quickly through selecting tests and configuring tests, setting up the connection, running the tests, and viewing the results. You can easily select individual tests or groups of tests with a mouse-click.
2
Configurability and guided connections
The N5394A DVI electrical test software provides flexibility in your test setup. It guides you to make connection changes with hookup diagrams when the tests you select require it.
For this test, select the test frequency from a range of choices
Test setup options are indicated for each test, including the present settings
Figure 2. In configuring the tests, you define the device to test, its configuration, and how the oscilloscope is connected.
For critical test parameters such as the horizontal voltage swing (Vswing) levels and worst-case intersections of the transmitter eye opening, you can choose to have the software automatically determine these values or manually set them on the displayed waveform.
Select measurement modes can be set from a measurement waveform
Figure 3. The DVI electrical test software allows automatic or manual determination of the horizontal voltage swing levels.
3
All DVI electrical compliance tests you perform are based on the DVI Compliance Test Kit test fixtures. The Clock Recovery Unit (CRU) is used for hardware clock recovery. The Test Point Access Plug Board (TPA2-Plug) is used for compliance tests at the transmitter. The Test Point Access Receptacle Board (TPA2-Receptacle) is used for compliance tests at the end of a DVI cable and the input to the receiver. Connection to the compliance test fixtures is via the Agilent InfiniiMax active differential probes. The DVI Compliance Test Kit also includes files and procedures for creating the pseudo-random and half-clock patterns for the DVI product being tested.
If more than one test setup connection is required, you will be notified here
You are prompted to make the appropriate connections for the set of tests
Figure 4. When you make multiple tests where the connections must be changed, the software prompts you with connection diagrams and/or photographs.
Figure 5. The Silicon Image DVI Compliance Test Kit CRU (Top board) and TPA2 fixtures (bottom boards).
4
Reports with margin analysis
In addition to providing you with measurement results, the N5394A DVI electrical test software provides a report format that shows you not only where your product passes or fails, but also reports how close you are to the limits specified for a particular test assertion. You select the margin test report parameter, which means you can specify the level at which warnings are issued to alert you to the electrical tests where your product is operating close to the official test limit defined by the DVI 1.0 specification for a given test assertion.
Summary of test results
Figure 6. The DVI electrical test software results report documents your test, indicates the pass/fail status, the test specification range, the measured values, and the margin.
5
Test results in an easy-to-read HTML formatted output Details for each specific test made
Test description
Test limits
Test results and waveforms
Figure 7. Additional details are available for each test including the test limits, test description, and test results, including waveforms, if appropriate.
Overall test description User set margin thresholds for warning and failure indicators Margin values indicate when the results are approaching test limits. Warnings and failures are high-
Figure 8. How close your device comes to passing or failing a test is indicated as a % in the margin field. A result highlighted in yellow or red indicates your device has tripped the margin threshold level for a warning or failure.
6
Measurement requirements
To use the N5394A DVI electrical performance validation and compliance software, you also need the DVI Compliance Test Kit (which contains the clock recovery unit, test point access fixtures, and cables), and at least two 3.5-GHz or higher InfiniiMax active differential probes (1131A, 1132A, 1134A, 1168A or 1169A) with appropriate probe heads (E2677A or N5381A solder-in or E2678A socketed). The DVI Compliance Test Kit is available from your local Silicon Image distributor.
Recommended test accessories
To complete your test setup, Agilent provides a wide range of cables, adapters, terminations, etc.
Model number 11667B 11636B 8493B Description Power splitter, DC to 26.5 GHz, 3.5-mm (f) connectors Power divider, DC to 26.5 GHz, 3.5-mm (f) connectors Coaxial attenuator (3, 6, 10, 20 or 30 dB), DC to 18 GHz, SMA connector SMA (f - f) adapter, DC to 18 GHz SMA (m - m) adapter, DC to 18 GHz Right-angle adapter, SMA (m - m) Right-angle adapter, SMA (f - m) SMA tee adapter (m, f, f), DC to 12.4 GHz SMA (m) to SMA (f) Adapter Cable kit, four 90-cm (36-in) SMA (m - m) cables Matched cable pair, two 90-cm (36-in) SMA (m - m) cables, propagation delay within 25 ps SMA (m) 50 termination
1250-1158 1250-1159 1250-1397 1250-1741 1250-1698 1250-1694 15442A 15443A
1810-0118
Table 1. Recommended test accessories.
7
Oscilloscope compatibility
The N5394A DVI electrical performance validation and compliance software is compatible with all Infiniium oscilloscopes with operating software revision 5.30 or higher for DSO80000 Series or 1.01 for DSO90000A Series. For oscilloscopes with earlier software revisions, free upgrade software is available at www. agilent.com/find/ infiniium_software The N5394A DVI electrical performance validation and compliance software is compatible with Agilent 80000 Series oscilloscopes with operating software revision A.03.90 or higher.
Data rate Up to 1.65 Gb/s
Recommended oscilloscope DSO90404A DSO90604A
Bandwidth of recommended oscilloscope 4 GHz 6 GHz
Note: The required minimum bandwidth for DVI measurements is 4 GHz. N5394A DVI electrical performance validation and compliance software will run on all Infiniium models. These include Agilent 54850 Series, DSO80000A/B Series, and DSO90000A Series.
Tests performed
The N5394A DVI electrical performance validation and compliance software performs the following tests as per the DVI 1.0 electrical specifications for add-in cards, motherboard systems, and cables as documented in section 4 of the base specification.
Assertion No.
Description Transmitter tests
4.7.4 4.7.5 4.7.6 4.7.7
Rise/fall times Skew Eye-pattern Jitter Cable tests
4.7.8 4.7.9
Eye-pattern Skew
Table 2. DVI electrical tests performed by the N5394A software.
8
Ordering information
To purchase the N5394A DVI electrical performance validation and compliance software with a new or existing Infiniium oscilloscope, order the following:
Model number N5394A 113XA GHz,
Description DVI electrical test software for Infiniium oscilloscopes InfiniiMax active differential probe (1131A 3.5 GHz, 1132A 5 or 1134A 7 GHz)
E2677A or N5381A E2678A
InfiniiMax solder-in differential probe head InfiniiMax socketed differential probe head
An alternative to purchasing the E2677A and E2678A is the E2669A: E2669A InfiniiMax connectivity kit for differential/single-ended measurements (contains one E2575A differential browser probe head, four E2677A solder-in differential probe heads, and two E2678A socketed differential probe heads)
Product Web site
For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/scope-apps
Related Literature
Publication Title Infiniium 80000 Series Oscilloscopes and InfiniiMax II Series Probes Agilent Infiniium DSO/DSA90000A Series Publication Type Data Sheet Data sheet Publication Number 5989-4604EN 5989-7819EN
9
Agilent Technologies Oscilloscopes
Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications
10
Remove all doubt
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to www.agilent.com/find/removealldoubt
www.agilent.com www.agilent.com/find/dvi
For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at:
www.agilent.com/find/contactus Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand
Agilent Direct
www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence.
(877) 894-4414 305 269 7500 (800) 829-4444
www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development.
1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008
Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700*
*0.125 /minute
www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium.
Germany
07031 464 6333**
**0.14 /minute
Windows(R) is a U.S. registered trademark of Microsoft Corporation.
Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus
Revised: July 17, 2008
Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2008 Printed in USA, September 15, 2008 5989-1526EN


▲Up To Search▲   

 
Price & Availability of N5394A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X